Flow Meter & Transmitter

  • Model LDBE Electromagnetic Flowmeter
  • Model LDBE Electromagnetic Flowmeter
Model LDBE Electromagnetic FlowmeterModel LDBE Electromagnetic Flowmeter

Model LDBE Electromagnetic Flowmeter

Model LDBE intelligent electromagnetic flowmeter is a fully intelligent electromagnetic flowmeter developed by our company with the most advanced technology. It is very different from the old analog or non-intelligent electromagnetic flowmeter, especially in service life, appearance, reliability, stability and measurement accuracy. LDBE intelligent electromagnetic flowmeter core uses high-speed central processing unit, equipped with backlight and wide temperature LCD in Chinese and English. It has complete functions, intuitive display and more convenient operation. In addition, we have designed a 4-6 multi-electrode structure, which further ensures the accuracy and stability of measurement, meets the field conditions without grounding ring, and reduces the workload of installation and maintenance.

Electromagnetic flowmeter is a flowmeter with high precision, high reliability and long service life, so we pay attention to every aspect of design, material selection, process and testing . The characteristics of this product are as follows:

1. The measurement accuracy is high. The induction voltage signal of the sensor has a linear relationship with the average velocity of flow. The measurement is not affected by the changes of density, viscosity, temperature, pressure and conductivity of the fluid.

2. Long service life, no movable parts, no obstruction parts in the pipeline, no pressure loss in the measurement.

3. Easy to use, easy to operate, high-definition backlight LCD display, English menu operation, users or according to the needs of the site, online range modification.

4. With RS485, RS232, Hart and Modbus communication protocol etc.

5. With the self-test and self diagnosis function.

6. Programmable low frequency rectangular wave excitation improves the stability of flow measurement and reduces power loss.

7. With 16-bit embedded microprocessor, the operation speed is fast and the precision is high.

8. Full digital processing, strong anti-interference ability, reliable measurement.

9. It has two-way flow measurement function and can display positive and negative flow.

10. The parameters are set flexibly and the flow converter has interchangeability.


Operating Principle

LDBE intelligent electromagnetic flowmeter is suitable for measuring volume flow of conductive liquid and slurry in closed pipeline, such as clean water, sewage, various acid-alkali-salt solutions, mud, pulp, pulp and food liquids. Therefore, it is widely used in chemical fibers, food, paper making, sugar making, water supply and drainage, environmental protection, water conservancy, steel, petroleum, chemical industry, pharmaceutical and other fields.

The measuring principle of LDBE intelligent electromagnetic flowmeter is based on Faraday's law of electromagnetic induction. When conductive liquid moves in the magnetic field to cut the magnetic induction line, the induction potential is generated in the conductor. Its induction potential E is as follows:

E=KBVD

Formula: K - - - Instrument Constant, B - - - Magnetic Induction Intensity, V - - - Measuring the Average Velocity in the Pipeline Section, D - - - Measuring the Internal Diameter of the Pipeline Section

When measuring the flow rate, the conductive liquid flows through the magnetic field perpendicular to the flow direction at the velocity V. The flow of the conductive liquid induces a voltage proportional to the average flow rate. The inductive voltage signal is detected by two or more electrodes directly in contact with the liquid, and sent to the converter through the cable for intelligent processing. Then the LCD display or conversion is made into standard signals 4-20mA and 0-1 KHz output.


Technical Parameters

Nominal diameter DN series (mm):

Pipeline PTFE lining: 10,15,20,25,32,40,50,65,80,100,125 150,200,250,300,350,400.450,500,600.

Pipeline Rubber lining: 40,50,65,80,100,125,150,200,300,350,400,500,600,800,1000,1200

Note: Special specifications can be customized

Flow Direction:

Positive and negative flow, net flow, Range ratio: 150:1. Repeatability error: measurement value (+0.1%)

Accuracy Class: Pipeline Type: 0.5, 1.0

The measured medium temperature:

Ordinary rubber lining: - 20 ~+60 ℃

High Temperature Rubber Lining: - 20 ~+90

PTEF lining: - 30 ~+100

High Temperature PTEF Lining: - 30 ~+180

Rated Operating pressure

Pipeline type: DN10—DN65≤2.5Mpa, DN80—DN150≤1.6Mpa,DN200—DN1200≤1.0Mpa

Flow measurement range: Flow measurement range convective velocity range is 0.3-15m/s.

Conductivity range: Electrical conductivity of measured fluid (> 5 u s/cm)

Most of the media consisting of water have the conductivity in the range of 200-800 mu s/cm, and the electromagnetic flux can be used.

Output current and load resistance: The maximum collector current of 4~20mA fully isolated load resistance < 750 ohm pulse frequency 0-1KHZ photoelectric isolation OCT external power supply < 35V on-line is 25mA.

Electrode materials: Stainless steel containing molybdenum, titanium (Ti), tantalum (Ta), Hastelloy (H), platinum (Pt) or other special electrode materials containing molybdenum.

Protection Class: Diving type: IP68, other IP65

Power supply: 85~265V,45~63HZ

Length of straight pipe section: Pipeline type: upstream (> 5DN), downstream (> 2DN).

Connection: Flange connection is used between flowmeter and piping. Flange connection size should meet the requirements of GB9119-88.

Explosion-proof mark: mdllBT4.

Ambient temperature: -25℃~+60℃.

Relative temperature: 5%~95%.

Total power consumption: Less than 20W.


Maximum and minimum flows must be in line with the following table

Calibermm

10

15

20

25

32

40

50

65

Qmin(m3/h)

0.0848

0.1908

0.3391

0.5299

0.8681

1.3565

2.1195

3.5820

Qmin(m3/h)

3.39

7.63

13.56

21.20

34.73

54.26

84.78

143.28

Calibermm

80

100

125

150

200

250

300

350

Qmin(m3/h)

5.4259

8.478

13.2469

19.0755

33.912

52.9875

76.302

103.8555

Qmin(m3/h)

217.04

339.12

529.88

763.02

1356.48

2119.5

3052.08

4154.22

Calibermm

400

450

500

550

600

700

800

900

Qmin(m3/h)

135.648

171.6795

211.95

256.46

305.208

415.422

542.592

686.718

Qmin(m3/h)

5425.96

6867.18

8478

10258.38

12208.22

16616.88

21703.68

27468.82

Calibermm

1000

1100

1200

1400

1600

1800

2000

2200

Qmin(m3/h)

847.80

1025.838

1220.832

1660.688

2170.368

2746.872

3991.20

4103.352

Qmin(m3/h)

33912

41033.52

48833.28

6647.52

86814.72

109874.88

135648

164134.08

Flow calculation formula: Q=V.Pi(D/2)2=0.002826V D 2 Formula: Q-m3/h, V-m/s, D-mm

Velocity range: 0.3-12m/s (extended range 0.1-15m/s is also possible)

Please note that the actual maximum working pressure must be less than the rated working pressure of the flowmeter. The maximum and minimum operating temperatures must meet the temperature requirements specified by the flowmeter. Determine if there is a negative pressure.

You can choose the corresponding electromagnetic flowmeter according to the flow in the table above. If the inner diameter of the selected electromagnetic flowmeter does not match the inner diameter of the current process pipeline, the pipe should be shrinked or expanded. If the pipe is shrinking, whether the pressure loss caused by pipe shrinkage will affect the process flow should be considered. Considering the product price, small-caliber electromagnetic flowmeter can be chosen to save cost.

When measuring clean water, its economic flow rate is 1.5-3m/s; when measuring easily crystallized solution, it is appropriate to increase the flow rate, 3-4m/s, which can act as self-cleaning and prevent adhesion deposition; when measuring abrasive fluids such as ore pulp, it is appropriate to reduce the flow rate, 1.0-2m/s, in order to reduce the wear of lining and electrodes. Practical applications rarely exceed 7m/s, and more rarely exceed 10m/s.


Selection of Electrode Materials

The material of the electrode should be selected according to the corrosivity of the fluid under test. Please consult the relevant corrosion manual and test the special fluid.

Material

Corrosion resistance

316L

Applicability: 1. Domestic water, industrial water, raw well water, municipal sewage.
   2. Weak corrosive acid, alkali and salt solutions

Hastelloy B

Applicability:

1.       Hydrochloric acid (concentration less than 10%) and all concentration of ammonium hydroxide alkali solution

2.       Sodium hydroxide (concentration less than 50%), all concentration of ammonium hydroxide alkali solution

3. Phosphoric acid, organic acid

Not applicable: hydrochloric acid

Hastelloy C

Applicability:

1. Mixed acid such as mixed solution of chromic acid and sulfuric acid

2. Oxidative salts such as Fe++, Cu+, seawater

Not applicable: hydrochloric acid

Titanium (Ti)

Applicability:

1. Salt, such as:

(1) chloride (chloride/magnesium/aluminum/calcium/ammonium/titanium, etc.)
(2) Sodium salt, potassium salt, ammonium salt, hypochlorite, sea water
2. Potassium chloride, ammonium hydroxide and barium hydroxide alkali solutions with concentration less than 50%
Not applicable: hydrochloric acid, sulfuric acid, phosphoric acid, hydrofluoric acid, barium cyan oxide alkali solution

Tantalum (Ta)

Applicability:

1. Hydrochloric acid (concentration less than 40%), dilute sulfuric acid and concentrated sulfuric acid (excluding fuming sulfuric acid)
2. Chlorine dioxide, magnesium chloride, hypochlorite, sodium cyanide, lead acetate, etc.
3. Oxidative acids such as nitric acid (including fuming nitric acid), aqua regia at temperatures below 80

Not applicable: alkali, hydrofluoric acid

Platinum (Pt)

Applicability: Almost all acid, alkali and salt solutions (including fuming sulfuric acid and fuming nitric acid)
Not applicable: Aqua regia, ammonium salt

Interlining Material Selection Instructions

The lining material should be selected according to the corrosiveness, abrasion and temperature of the tested medium.

Lining material

designation

function

MAX TEMP

Applicable liquid

pipe diameter

rubber

CR

Medium abrasion resistance, corrosion resistance of acid and alkali salts with low concentration

80

Tap water, industrial water, sea water

DN50-2200

PU

Excellent wear resistance, poor acid and alkali resistance

60

Pulp, pulp, etc.

DN25-500

Fluoroplastics

F4 or
PTFE

Chemical performance is very stable, resistant to boiling of hydrochloric acid, sulfuric acid, Aqua regia, concentrated alkali corrosion

180

Corrosive acid-base salt liquids

DN25-1200

F46 or
FEP

Chemical properties are slightly inferior to those of F4

120

Corrosive acid-base salt liquids

DN15-200

F4 or ETFE

Chemical properties are slightly inferior to those of F4

 

Corrosive acid-base salt liquids

DN250-2200

Plastic

PO

Chemical stability

60

sewage

DN50-2200

PPS

 

110

hot water

DN50-2200

Selection of Protection Class

IP65: Sprinkler-proof type, which allows the tap to spray water from any direction to the sensor. The sprinkler pressure is 30kPa, the water output is 12.5 L/s, and the distance is 3 m.

IP68: Diving type, long-term working in water.

The protection level should be chosen according to the actual situation. The sensor should be installed below the ground. If it is often flooded, IP68 should be selected. The sensor should be installed above the ground and IP65 should be selected.

Selection of additional functions

The basic type of LDBE intelligent electromagnetic flowmeter has been shown, and the output functions of 4-20mA and 0-1kHz alarm can be selected according to the actual situation.

Split type installation: Sensors should be installed below the ground or for other reasons. Split type installation should be selected.

RS-485 communication: For communication between converter and other equipment, RS-485 communication function should be selected.